Appendix5. Summary of Values Recommended by These Guidelines No Item Value 1 Excavation and backfilling duration ≤3days 2 Excavation notification to the other utilities ≥ 5 days before commencement operators 3 Distance of cable from the edge of shoulder 1.5m 4 Minimum distance of the cable from the off of roadway 2.5metres 5 Interval distance between FOC and existing 1m underground infrastructure 6 Trench depth ≥80cm 7 Trench depth while road crossing ≥1meter 8 Visible tape along the trenches below 30 cm ground surface. 9 Interval distance between two visible tape 300m to 500m marker indicating cable route 10 Distance of Manhole/Hand hole from the 2metres edge of shoulder 11 Minimum distance of the Manhole/Hand hole from the off of roadway 3m 12 Accomplishment report submission ≤5 working days from mentioned on the schedule 13 As-built documentation report submission ≤30 working days from the date mentioned on the schedule 14 Right of way permit delivery 10 working days 15 Right of way permit validity 3months 18 the date